DRTCE-AO
AO Series Intellectualized DC Load
Functions & Features
1) Small volume, light weight and big power, heavy current
detection capability of storage battery
2) Adopt new-type, low-heating special |
| |
 |
|
for
load and advanced control technology
3) Battery pack polar protection function
4) Voltage/current sampling time is 0.05 seconds. It adopts
different data to store frequency automatically according
to discharge time setup
5) It sets up three conditions to stop discharging when performing
discharge test:
- whole
pack voltage
- discharge
time
- discharge
capacity
- manually
stop the test process
6)
Signal input and power supply
input, and communication interface
adopt high-ranking electrical
isolation, the instrument can
bear 1000Vrms withstand voltage
for 1 minute, and safety protection
degree is up to IP30
7) Protection design technology integrating software with
hardware, any mistaking key operation can not cause any damage
of equipment, instrument or storage battery
8) Save 10 groups of test data; the user can query, delete
and upload the data
9) Powerful function of upper computer, friendly interface,
manage, print and analyze the data, statistic report, and
automatic creation of test report
10) With COM and USB interface
Technical
specs available upon request. |
|
 |
|
 |
 |
 |
DRTCE-IA
IA Series Storage Battery Intellectualized Activator
Functions:
1) Cell activation:
Perform cell activation on the state of online floating charge
or offline. Users should set up activation and cycling times,
single-activation |
| |
|
|
charge
time, protective voltage parameters
before activation; it can display
battery voltage, charge/discharge
current, charge/discharge capacity,
charge/discharge time and etc;
users can set up activation cycling
and also stop the activation
manually.
2) Cell check discharge:
Perform constant current discharge for cell. Users should
set up discharge time, discharge capacity, cut-off voltage
and etc before discharge; it can display discharge current,
battery discharged capacity, battery voltage, discharge time
and etc; users can manually stop the discharge.
3) Cell charge:
When the battery is on the state of online floating charge
or offline, it can perform automatic charge for battery,
users should set up charge current, charge time, cut-off
voltage and etc, the instrument can display charge current,
battery charged capacity, battery voltage, charge time and
etc; users can manually stop the discharge.
Features:
- Data
storage - large capacity.
Save 10 groups of activation
data, 10 groups of check
discharge data, and 10 groups
of charge test data. Users
can query, delete and export
the data.
- With
RS232 interface and USB interface.
users can perform long-term
historical data storage and
analysis.
- When
the instrument detects abnormal
phenomenon of battery or
working is abnormal, it automatically
stops testing for protecting
battery.
- The
activation adopts integrated
design with monitoring unit
and power unit. The monitoring
unit adopts high-speed A/D
and D/A, and power unit adopts
new-type parts.
This
software is English designed,
and it can automatically create
voltage/current histogram,
curve chart, and test report
(including Excel table and
WORD document.)
Technical
specs available upon request. |
|
 |
|
 |
 |
 |
DRTCE-DC
DC Series Fully-Automatic Battery Charger
Functions
and Features:
1) Control chip of power supply adopts import military use
grade IC, other parts could adopt import industrial grade parts,
the design of charger is optimized and reasonable, the production
technics is serious and complete in order to guarantee the
reliability and stability of machine. |
| |
|
|
2)
Power switch tube adopts IGBT
parts made in Japan in order
to improve the reliability of
whole machine.
3) Perform charge according to charge characteristics curve
of battery, designed charge mode is :“constant current→(voltage
stabilizing value of uniform charge)voltage fixing and current
decreasing→(automatic judge is shifted into) floating
charge of trickle”, it possesses the advantages such
as quick charge speed, high charge recovery efficiency, no
need of person on watch, no over charge danger for a long
time, ensure service life of battery and etc.
4) Digital voltage meter/current meter display.
5) Timing function: besides Full-automatic three wave band
charge mode, the user could also select manual timing charge
mode.
6) It possesses over-current protection of AC input, output
short circuit and battery polarity reverse protection, this
function adopts electromagnetic air switch and electronic
protection, quick feedback speed, and long service life.
It also possesses intelligent temperature-controlled fan
cooling and over-temperature automatic turn-off protection
function, and ensures the user use it safely.
7) Small volume, light weight, convenient for movement.
Technical
specs available upon request. |
|
 |
|
 |

DRTCE
- AG |
 |
DRTCE
- AGV
|
 |
|
|
AG
Series Storage Battery Comprehensive
Tester
Functions & Features:
1) Quick capacity test function: under the state of offline
state, it just takes 5 to 20 minutes to measure the actual
capacity of all cells.
2) Perform check discharge for battery pack according to
different discharge rate.
3) Online monitoring for battery pack: when the battery pack
is under the state of online discharge, uniform charge and
floating charge, perform real-time online monitoring for
all cells. The monitoring includes pack voltage, cell voltage,
charge/discharge current, monitoring time of battery pack,
charge/discharge capacity of battery pack and etc.
4) Judge battery performance quickly and accurately.
5) It sets up four conditions to stop discharging when performing
check discharge test:
- whole
pack voltag
- cell
voltag
- discharge
tim
- discharge
capacity
6)
It can also manually stop the
test process.
7) LCD with high brightness and large screen, marine blue
background.
8) Simple operation, English menu, and humanized interface.
9) It can test large-capacity battery pack.
10) With automatic testing protection function.
11) Automatically display all test results and put forward
maintenance suggestions.
12) Powerful PC management software function: friendly interface.
store, print, analyze the data, statistic report, and create
test report automatically. Search historical record quickly.
Zoom in and out the graphs of voltage, inner resistance and
capacity.
Technical
specs available upon request. |
|
|
 |
 |
 |
DRTCE-WI
Wireless Transmission Battery Voltage Collection Module
Features:
1) Wireless transmission storage battery testing system is
comprehensive fruit integrating with several technologies of
battery measurement, wireless communication, computer information |
 |
|
|
processing
and etc.
2) Patent technology, adopt wireless communication for transfer
data, easy operation and safety.
3) Real-time monitoring cell voltage, quick and accurate
data collection, record the change at each moment during
battery charge and discharge, guarantee accurate judgment
of battery performance, and prevent from measurement error
caused by wiring.
4) Complete anti-opposition measure, even if module measurement
signal line is connected oppositively, it could not cause
the damage of battery and module.
5) High-accuracy of wireless module (16 bit AD), low power
consumption, small volume, light weight, easy operation,
and reliable security.
6) Single unit of system could test several packs of batteries
simultaneously, the total of measuring battery quantity could
be up to255, and with high testing efficiency.
6) The system possesses RS232/485 communication interface,
which could perform real-time data communication, or be controlled
by other intelligent equipment.
Technical
specs available upon request. |
|
 |
|
 |
 |
 |
DRTCE-AMS
AMS Battery Online Monitor System |
| |
 |
|
Instruction
AMS system can operate complete monitoring for inner resistance
of cells.
6 reasons for selecting this system:
- Ensure
power supply of battery
- Determine
potential faults of cells
and deteriorated battery
in avoidance of equipment
paralysis after power-off
- Know
real-time status of battery,
especially battery capacity
attenuation; avoid replacing
battery blindly, decrease
battery replacement expenses
- Realize
network centralized management
via LAN, decrease maintenance
and management cost;
- Improve
security of operators;
- Easy
installation
Features
1) Detecting all battery faults and inner connection problems
before leading system.
2) 24 hours online monitor, record, save and analyze batteries
and cell status.
The data includes:
- Total
voltage of battery pack
- Ambient
temperature
- Floating
current
- pack
current
- Charge/discharge
current
- Cell
inner resistance
- Cell
voltage
- Discharge
data & curve
Functions
- Real-time
monitor for discharge current
- Accurate
power supply faults analysis,
and bad battery locating
- Professional
software with clear data,
graphic display of test results
and alarm condition
- 7×24
hours alarm monitor, and
ensure system availability
- Modularized
solutions
- Remote
visit via LAN and WAN. Reduce
maintenance cost and periodic
service
- Specific
historical record and battery
replacement time
- Testing
inner resistance of battery
by direct current method
(national patent technology)
- Network
battery online management
technology (Web publishing)
Technical
specs available upon request. |
|
 |
|
 |
 |
 |
DRTCE-ALU
ALU600 UPS Storage Battery Tester
General
The SAT-ALU600 UPS Storage Battery Tester is the special
instrument for testing UPS battery pack (16-40 section cells)
and lead-acid battery pack with 12V cell, which possesses
the functions of "online monitoring," "check
discharge," etc.
This
equipment adopts current advanced
testing technology, and obtain
a series of breakthrough of
research and application of |
| |
 |
|
new
technology, new parts, new material
and new technics, which is special
testing instrument for storage
battery performance detection.
With big discharge power, small
volume, light weight, and complete
function of upper computer data
management software, which could
greatly decrease daily workload
of storage battery test and maintenance.
Main
Functions and Features:
- Online
monitoring: When the
battery pack is under the
state of online discharge,
uniform charge, floating
charge, it could perform
real-time monitoring for
battery pack and cell; it
includes the whole pack voltage,
cell voltage, whole pack
charge/discharge current,
whole pack charge capacity,
whole pack discharge capacity,
monitoring time and etc;
- The
user could set up monitoring
cell quantity.
- Check
discharge: It could
perform constant current
check discharge taking advantage
of intelligent dummy load
and set up “discharge
current”, “discharge
time”, “discharge
capacity”, “whole
pack off protection voltage”, “cell
off protection voltage” and
parameters after the battery
pack is removed from the
system, the tester would
automatically carry out discharge
function, and display discharge
current, battery discharged
capacity, whole pack voltage,
cell voltage, discharge time
and etc at real time; when
the battery pack reaches
discharge voltage setting
value, off discharge capacity
setting value, off discharge
time setting value, any cell
voltage is below off cell
voltage setting value or
manually stopping operation
could stop discharge test.
- The
user could set up discharge
cell quantity.
- It
could save 10 groups
of online monitoring
data and 10 groups
of check discharge
testing data; the user
could perform query,
deletion and upload.
- The
data could upload to
PC by serial port,
and could also export
to U disc.
- Automatic
protection:
- When
detecting whole pack or
cell is abnormal and working
of tester is abnormal during
test, the tester would
automatically stop the
test in order to protecting
the battery.
- The
mainframe of tester adopts
the design integrating
monitoring unit with power
unit, the power unit adopts
new-type high-efficiency
parts, and it is a storage
battery tester with small
volume and high efficiency.
- Humanized
operation interface, simple
operation, clear flow,
the each operation has
English cue.
- Aquarine
blue, high-brightness and
large-screen LCD, and the
display effect is clear
and great.
- Upper
computer data management
software possesses powerful
function, friendly interface,
and provides data management,
print, analysis, report
form statistic, automatic
creation of test report
and etc.
Technical
specs available by request. |
|
|
 |
 |
|
DRTCE-CFJ
C | FJ Storage Battery Intelligent Charge & Discharge
Detector
Intelligent Charge, Discharge and Detection: |
| |
 |
|
SAT-C
| FJ Storage Battery Intelligent
Charge & Discharge Detector
is a detector integrating with
charge, discharge, detection,
online monitoring and activation.
It could reduce company cost,
decrease labor intensity of maintenance
staff, and provide complete and
scientific detection means for
battery and UPS power supply
maintenance. It is applied in
telecom, base station, power
and other departments, perform
deep discharge according to the
needs, and then charge; it could
also activate battery pack or
cell taking advantage of strong
charge function of constant current,
and make the battery keeping
full power state at any moment
and lengthen battery service
life.
Main
Functions and Features:
- Integrating
with charge, discharge, detection,
online monitoring and activation,
complete function, and one
machine with many operations
- Intelligent
three-stage charge, constant
current discharge, real-time
online cycle detection for
cell parameters, and it could
set and control voltage,
current, time, capacity and
etc, and automatically complete
testing, monitoring and activation
for all kinds of parameters
of battery pack
- Adopt
new-type power consumption
parts, safe and without infrared
phenomenon, long service
life
- Application
of data transfer technology
from singlechip machine to
U disc could solve large-capacity
data memory problem
- The
data could transfer by U
disc or upload to computer
for background processing
by RS232 connector and automatically
create all kinds of forms,
and the user could clearly
know the battery performance
- Portable
design with small volume
could make easily operation
of user
Technical
specs available upon request |
|
 |
|
 |
 |
 |
DRTCE-IVT
IVT Battery Sensor
Description
The IVT battery sensor measures a
battery's current (I), voltage (V), and
temperature (T). A robust 100 micro-ohm
shunt is used to measure the current while
providing low voltage drop and significant
current carrying capacity. The sensor
features a Local Interconnect Network (LIN) or Controller
Area Network (CAN) |
| |
|
|
interface
for data and diagnostic communication.
Typical
Application
Most battery management systems require calculation of battery
state of charge (SOC) and may also require battery state
of health (SOH). The IVT accurately measures the current
into and out of the battery as well as the battery voltage
and battery temperature to enable reliable
and accurate SOC and SOH calculation. When the IVT sensor
is integrated into a vehicle along with active battery management,
the system can deliver improved fuel economy, increased battery
life, and increased energy system availability. Battery management
reduces fuel consumption when the IVT/Battery management
system is equipped with alternator voltage
output control as part of the system.
Performance
Advantages
While the vehicle is running, the IVT battery sensor accurately
measures the charge and discharge of the battery so the SOC
can be continuously updated. Controlling and maintaining
the SOC helps reduce fuel consumption and extend the battery
life. In addition, SOC and SOH
support other valuable features for the vehicle.
Performance
specifications available upon
request. |
|
|